● Code :
A1-1211
A1-1213
● Error message :
ctuator Motor Failu
● Symptom / Cause :
Fuser motor does not operate.
Fuser motor is operating but is recognized as stop sta
● Troubleshooting method :
1. Turn the machine off. Check if there is any foreign
2 Remove the fuser unit and reinstall it
.
3. Turn the machine on. Is the problem solved?
If not, go to the next.
4. Turn the machine off.
Open the engine/video shield door.
Check if the fuser/exit motor connector is connecte
If the problem persists, replace the fuser/exit drive
5. If the problem persists, replace the fuser unit.
● Replacement part
- JC31-00123B (MOTOR BLDC)
Service Manual
SCX-8030/8040 series
7-
hooting
re #A1-1211: Turn off then on.
re #A1-1213: Turn off then on.
atter around the fuser unit.
otor.
SAMSUNG ELECTRONICS