4.AlignmentandTroubleshooting
ErrorCode
A3–3311
A3–3312
Errormessage
ActuatorSensorFailure#A3-3311:Callforserviceiftheproblempersists.
ActuatorSensorFailure#A3-3312:Callforserviceiftheproblempersists.
Symptom
Theoutertemperaturesensorisdefective.
Troubleshootingmethod
1)Turnthemachineoffthenon.Iftheerrorpersists,turnthemachineoffagain.
2)Enterthetechmode.Checkthetemperaturesensoroutput.
3)Ifthesensorisdefective,replaceit.
4)IfthetemperaturesensorisOK,replacethemainboard.
ErrorCode
A3–3320
Errormessage
Notproperroomtemperature.Changeroomtemperature.
Symptom
Thevalueoftheoutertemperaturesensorisoutofnormalarea.
Troubleshootingmethod
1)Checkifthemachineisinstalledintheproperarea.
2)Ifthetemperaturesensorisdefective,replaceit.
Copyright©1995-2016SAMSUNG.Allrightsreserved.4-36