4.Troubleshooting
ErrorCode
A2–1210
A2–2110
Errormessage
SMPSFanFailure:#A2-1210.Turnoffthenon.Callforserviceiftheproblempersists
FuserFanFailure:#A2-2110.Turnoffthenon.Callforserviceiftheproblempersists
Symptom
MainfanorSMPSfanisnotoperational.
Troubleshootingmethod
NOTE
SMPSfanerror:A2–1210
Mainfanerror:A2–2110
1)Turnthemachineoffthenon.
2)Checkifthecorrespondingfanconnectorisconnectedcorrectly.
3)IftheconnectionisOK,EnterSVCmodeandexecutefantest.
(Diagnostics>EngineDiagnostics>EngineTestRoutines)
4)Ifthefanisnotoperational,measurethefanpower.
a)If24Vpowerisgenerated,replacethedefectivefan.
SMPSfan:JC31-00152B
Mainfan:JC31-00161A
b)If24Vpowerisnotgenerated,
Measurethe24VpowerontheSMPSboard.IftheSMPSboardisdefective,replaceit.
IftheSMPSboardisnormal,replacethemainboard.
5)Ifthefanoperationisnormalbuttheerrorpersists,
a)Replacethefan.
b)Iftheerrorpersistsafterreplacingthefan,replacethemainboard.