Samsung SL-M4080FX - Temperature Sensor Failure: #A3-3311. Turn off then On. Call for Service if the Problem Persists; Temperature Sensor Failure: #A3-3312. Turn off then On. Call for Service if the Problem Persists; The Room Temperature Is Not Suitable for this Set Use. Please Adjust Room Temperature

Samsung SL-M4080FX
222 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.Troubleshooting
ErrorCode
A3–3311
A3–3312
A3–3320
Errormessage
TemperatureSensorFailure:#A3-3311.Turnoffthenon.Callforserviceiftheproblempersists
TemperatureSensorFailure:#A3-3312.Turnoffthenon.Callforserviceiftheproblempersists
Theroomtemperatureisnotsuitableforthissetuse.Pleaseadjustroomtemperature
Symptom
Outertemperaturesensorisdefective.
Troubleshootingmethod
1)Turnthemachineoffthenon.
2)Checkifthemachineisinstalledinproperenvironment.
3)Checktheharnessconnectionbetweenmainboardandtemperaturesensor.Reconnectthesensorharness.
4)Iftheproblempersists,replacethemainboard.
Copyright©1995-2013SAMSUNG.Allrightsreserved.4-68