4.Troubleshooting
ErrorCode
S2–33xx
Errormessage
Error:#S2-33xxTurnoffthenon
Calibrating...PleaseWait
Waitdelaytimeforlowerxingtemperature…
Supplyingandmixingtonertodeveloperunit.Pleasewait...
Symptom
Thiserrorshowstheenginestatus.
Troubleshootingmethod
S2–3310:Warm-upstatus
S2–3311:Readystatus
S2–3312:Printingstatus
S2–3313:PowerSavestatus
S2–3314:Errorstatus
S2–3315:Recoverystatus
S2–3316:Waitstatus
S2–3317:EDCmodestatus
S2–3318:Lowpowerstatus
S2–331C:Temperatureinmachineisoverheated.
S2–331D:Temperatureinfuserisoverheated.
S2–3321:Tonerissupplying.
Whentheseerrorsdisplay,waituntilthemessagewillbedisappearedorturnthemachineoffthenon.