2.ProductSpecicationsandDescription
2.5.3.1.Development
Thismachineusesaone-componentdevelopmentsystemandhasaimagingunit(whichisincludedinthedrumunit).
Thenewunitcontains20goftonerthatissuppliedtothesupplyrollerbytheagitator.Andthenthetonerissuppliedtothe
deverollerbythesupplyroller.AfterthetonerexitsfromtheDr.blade,itformsadeveloperbrush.Thentonerisattractedto
thesurfaceoftheOPCDrumonlyinareasthecorrespondstotheimagearea.Thediameterofthedeverolleris20mm.
Theupperaugerfunctiontosupplythetonertothebothsidesregularly.
2-29Copyright©1995-2013SAMSUNG.Allrightsreserved.