8-9)
Various
Option
Function
)
m
When
pressing
the
temperature
control
s/w
of
freezer
and
vacation
s/w
for
12
sec.
continuously
at
the
same
time,
display
is
converted
into
option
setup
mode.
When
display
is
converted
into
option
setup
mode,
every
display
except
for
temperature
display
of
freezer
and
Refrigerator
turns
off
like
the
following.
REFRIGERATOR
rite
=
On
display
like
the
above,
temperature
display
of
Refrigerator
indicates
items
of
option,
and
temperature
display
of
freezer
indicates
setup
value
for
each
item.For
the
temperature
display
of
Refrigerator,
when
temperature
control
s/w
is
pressed,
option
items
increase,
and
when
vacation
s/w
is
pressed,
option
items
decrease.
For
the
temperature
display
of
freezer,
when
temperature
control
s/w
is
pressed,
option
setup
value
increases,
and
when
vacation
s/w
is
pressed,
option
setup
value
decreases.
If
waiting
for
20sec.
after
changing
option
by
controlling
s/w,
option
setup
value
is
saved
to
EEPROM,
and
option
setup
mode
is
canceled
automatically
and
restored
hormal
display.
For
example,
if
you
want
to
shift
temperature
of
Refrigerator
by
-3°C
by
controlling
option,
follow
the
processes
of
below.
=
1)
Press
temperature
control
s/w
and
vacation
s/w
of
freezer
for
more
than
12
sec.
simultaneously
:
all
displays
become
off
except
temperature
display
of
freezer
and
Refrigerator.
2)
Pressing
temperature
control
s/w
of
Refrigerator
for
one
time,
“1”
is
indicated
on
Refrigerator
display
:
If
indication
“1”
is
displayed
on
Refrigerator
display,
it
shows
temperature
setup
of
Refrigerator,
and
current
temperature
setup
value
of
Refrigerator
is
indicated
on
temperature
display
of
freezer.
3)
If
temperature
display
of
freezer
indicates
“9”
this
time,
check
value
which
is
set
at
present
from
the
table
in
the
next
page.
In
this
case,
you
can
see
that
temperature
is
changed
to
+1.0°C
compared
to
the
Standard
temperature
according
to
the
table
:
Here,
in
order
to
change
by
-3.0°C,
(+1.0°C)
+
(-3°C)
=
-2.0°C
is
calculated.
4)
Now
Refer
to
the
table
on
the
next
page
to
change
temperature
to
-2°C..
Press
temperature
s/w
and
quick
freeze
s/w
of
freezer
for
temperature
control
display
to
indicate
“4”:
Waiting
for
20sec.
after
setup,
MICOM
saves
setup
value
to
EEPROM
and
returns
to
the
normal
display
and
cancel
option
setup
mode.
*
Caution
When
product
is
delivered,
option
function
is
set
to
EEPROM
from
the
plant,
therefore,
Refrain
from
intentional
change
except
for
special
case.
Option
function
setup
is
completed
only
after
it
is
returned
to
the
normal
display
after
20sec..
So
do
not
turn
power
off
before
display
returns
to
the
normal
state.

Related product manuals