8-7.
LOAD
OPERATION
circuit
part
REFERRENCE
RED-RED
BLU-BLUE
ORG-ORANGE
BRN-BROWN
~
PNK-PINK
GRY-GRAY
WHT-WHITE
YEL-YELLOW
~
BLK-BLACK
PRP-PURPLE
W/BLK-
WHITE/BLACK
S/BLU-
SKY
BLUE
When
“High”
signal
is
supplied
to
INPUT
of
IC03
(ULN2003A)
at
MICOM
PIN
NO
#22
(P15),
IC
comes
to
be
turned
on.
At
this
time,
if
V12
(DC
12V)
supplied
to
the
lower
COIL
of
COMP
RELAY
runs
into
GROUND
through
OUTPUT
of
IC03,
magnetic
field
will
occur
at
CORE
and
then
make
contact
point
ON.
This
approves
220
V
to
COMP
LOAD
to
make
COMP
ON
and,
if
MICOM
PIN
NO
#22
becomes
“Low”
state,
IC
arnes
to
be
TURN
OFF
state
to
make
current
not
running
to
COMP
RELAY
COIL,
to
make
RELAY
contact
point
OFF
state,
and
then,
finally
to
stop
COMP.
1.
Explanation
of
co-operation
of
COMP
and
F,
R-Defroster
HEATER
O
COMP
RELAY
he
O ©
ne
ee
-Defroster
Heater
R-Defroster
Heater