10-11)
When
Light
of
Dispenser
does
not
operate,
ao
)
LIGHT
LAMP
is
normal?
Replacement
of
LAMP
Check
MICOM,
Replacement
of
PCB
Check
and
Replacement
of
IC03
N
Replacement
of
RELAY
RY74
MICOM
PORT
#17
on
MAIN
PCB
is
1C03
PORT
#12
is
less
than
DC1V?
Contact
of
LIGHT
RELAY
RY74
is
ON?
Contact
state
of
CONNECTOR
CN72
on
PCB
other
wire
connection
state,
Contact
trouble
of
Connector
of
Hinge-Upp
of
the
Freezer,
other
things
*
Information
,
ee
eee
pear
eis
Lamp
function
turns
off
automatically
after
20
seconds
when
there
is
no
OFF
signal
for
20
seconds
after
the
selection
of
Lamp
function.
It
is
operated
by
operating
LIGHT
RELAY
(RY74)
on
MAIN
PCB
and
so,
when
there
are
troubles
with
RELAY
and
wire
connection,
light
may
not
be
on.
So,
check
RELAY
operation
and
the
snapping
of
LAMP
itself.
.