EasyManua.ls Logo

Samsung SR-S26NTA - Page 39

Samsung SR-S26NTA
101 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
(2) When ÒPeepÓ continues to sound,
Whether
Forced-Defrost or Forced-Operation
is selected?
START
Cancellation of Forced-Defrost
or Forced-Operation
Buzzer sounds in spite
of re-POWER ON?
MAIN-PCB is normal
Check of Connector
(CN40), lead TOUCH, insertion
of particles, SHORT
N
N
Y
Y
Information
ÒPeepÓ alarm does not sound except the case of Forced-Operation, Forced-Defrost, and finding
of abnormal things during Self-Diagnosis.
On the finding of abnormal things during Self-Diagnosis, the relevant things can be found on
PANEL-DISPLAY. If PANEL-DISPLAY is normal and ÒPeepÓ continues to sound, it is most
likely that Forced-Operation or Forced-Defrost is selected.
(3) When PANEL-DISPLAY does not turn on,
Connector
insertion of Hinge-Upp Cover
is normal?
START
Re-insertion of Connector,
Repair of Contact trouble
MAIN-PCB
connector (CN50) is normally
inserted?
Re-insertion of
MAIN-PCB connector
Connector
insertion at PANEL-DISPENSER
part is normal?
Re-insertion of Connector,
Repair of contact trouble
Replacement of PANEL-DISPLAY
N
N
Y
Y
N
Y
45