28
Part Name Descriptive Picture How To Do
Ĺ Tilt the unit backward and take out the
drain pump.
ĺ Disconnect the incoming water hose and
the wire harness.
(Caution: Check if the unit is plugged out.
There is possibility of electric shock.)
Ļ Separate the Hose Filter Tub and the Drain
Hose.
Ć CHECK POINT
1. Remove the Drain Filter and check if there are foreign substances (coin, buttons, etc)
blocking inside - If so, clear the inside.
2. Check if the wire harness is connected properly - If not, connect it properly.
3. If water leaks, check if the Clamp Hose and the Cap Drain are assembled tightly
- If not, assemble them tightly.
Remove the water remaining inside by turning the Filter counter clockwise.