6-2-6. Driving Part Checking
ƹ Confi rm The Output Of DC5V, When The Every Part Of Micom Number Check,
According To The Some Problem Condition
ex) When The Drain Is Not Operating But Pump Motor Is Operating, Check
The 5Voltage Of Micom
Ć Check The Micom 18th In The Above Method When The Cold Water Is Bad
Micom Number 31 Is
5 Voltage?
Micom Bad
The Part Of aIs
0 Voltage?
Check R47, TRIAC4
NO
NO
YES
YES
Check The IC6
KID65003AP
¤˝