24 _ Troubleshooting
Error Type
For USA
Causes Remarks
LED LCD
Overow Error OE
- Waterissuppliedcontinuallybecausethewaterlevel
detectiondoesnotwork.
- Becausethedrainhoseiscloggedandthereis
aninjectionerror(atanarrowsection),thewater
leveldetectiondoesnotworkandwaterissupplied
continually.
- Waterissuppliedcontinuallybecauseoffreezingor
becausethereisforeignmaterialinthewatersupply
valve.
- Thiserrormayoccurwhenthewaterlevelsensoris
degraded.
Thiserroroccurs
becausethe
waterlevel
sensorterminal
isoutofplace.
Temperature
Sensor Error
tE
- Thewashingheaterinthetubhasanerror.(Contact
error,temperaturesensorfault)
- Theconnectorisconnectedincorrectlyoris
disconnected.
- Ifthewaterlevelsensoroperateswithoutwater
becausethewaterisfrozenorforanyotherreason
andthetemperaturesensorengagedatthebottomto
preventoverheatingforthewashingheaterdetectsa
temperatureof100to150˚C,thewashingmachine
turnstheinputpoweroff.
Heatersensor
fault
:Whenthe
connectoris
connected
incorrectlyor
hasawire
disconnectedor
contacterror
Unbalance
Error
dc
- Aslaundrycausesthiserror,checkthelaundry.
- Findthereasonfortheimbalanceandsolveitas
directedintheusermanual.
Foaming
Detected
Sd
- Thisoccurswhentoomuchfoamingisdetected.Itis
alsodisplayedwhilefoamingisremoved.Whenthe
removalisnished,thenormalcycleproceeds.“Sd”
or“SUdS”isdisplayedwhentoomuchfoamingis
detectedand“End”isdisplayedwhentheremovalof
thefoamingisnished.
(Thisisoneofthenormaloperations.Itisanerrorfor
preventingnon-sensingfaults.)