Door Unlock Check Test 1 Test 2
Connector CN6 Pin 2 (Gray) and RY1 Pin 1 (Blu) When Door is Unlocked there is a
pulse of 120VAC for a few millisec-
onds.
With Power Off, the resistance
between CN1 Pin 1 (Blk) and Power
Relay pin 2 (Blu) will be between
47 - 57Ω
Door Lock Check Test 1 Test 2
Connector CN6 Pin 1(Black) and RY1 Pin 1 (Blu) When Door is Locked there is a pulse
of 120VAC for a few milliseconds.
With Power Off, the resistance
between CN1 Pin 2 (Wht) and
Power Relay pin 2 (Blu) will be be-
tween 47 - 57Ω
Drain Motor Check Test 1 Test 2
Connector CN1 Pin 3 (Vio) and RY1 Pin 1 (Blu) 120VAC with the pump On and 0VAC
with the pump off
With Power Off, the resistance
between CN1 Pin 3 (Vio) and
Power Relay pin 2 (Blu) should be
13.9Ω
Water Valve Check Test 1 Test 2
Connector CN6 Pin 2 (Gray) to CN1 Pin 5 (Pink),
Pin 4 (Brown) , Pin 7 (Yellow), Pin 8 (Blue), Pin 9
(Red)
120VAC with the Valve On and 0VAC
with the Valve off
Power Off, valve resistance is from
1202Ω - 1245Ω
Error Type Error Mode Details
LED LCD
Water Level Sensor
LE
8
Check the Hose where the sensor is connected, may be loose,
pinched, damaged or clogged. Also check the sensor it may be
disconnected or defective. The Main PCB may also be defective
Motor Drive Error or
Hall Sensor error
3E
Check the motor drive connector, it may be loose. The hall sensor
may be disconnected, loose or damaged . Check for a foreign ob-
ject inside the motor or motor damage. The stator might be loose
or damaged. The drum might be overloaded from too many clothes
or the relay or PCB might be defective.
E3
bE
25
Water Supply
Error
nF
3
Check the water valve wiring harness.
Check whether the water supply valve is clogged with foreign ma-
terial and whether water is supplied properly.
Check for reversed fill hoses
Check water temperature, if sensed as higher than 50 ˚C in the
Wool or Lingerie cycle it will create error.
Check the relays, if they operate correctly replace the Main PCB.
Fill Hoses Reversed nF1
Correct Hot/Cold hose connections
System Error SF1
SF2
SF3
Replace PCB