4.AlignmentandTroubleshooting
ErrorCode
U2-6120
U2-6140
Errormessage
Error#U2-6120Turnoffthenon
Error#U2-6140Turnoffthenon
Symptom
LSUMotordoesnotworknormally./LSUHsyncsignalisabnormal.
Troubleshootingmethod
1)CheckiftheLSUharnessonthemainboardisconnectedproperly.
2)IfitisOK,checkthattheLSUharnessonLSUboardisconnectedproperly.
3)CheckiftheLSUharnessisdefective.
4)Iftheproblempersists,replacetheLSU.
5)IftheproblempersistsafterreplacingLSU,replacethemainboard.
4-63Copyright©1995-2017SAMSUNG.Allrightsreserved.