SILENT DESIGN Axial Extractor Fans Installation

Qualified Electrician and Installation Requirements

Installation must be done by a qualified electrician following national electrical standards.

Product Quality and Receipt Verification

Verify product quality, model, and rating details upon receipt as per ISO 9001 standards.

Mounting and Airflow Considerations

Ensure proper mounting, hole diameter, and unobstructed airflow for optimal performance.

Electrical Connection Preparation

Identify components and prepare for electrical connection according to diagrams.

Electrical Connection Details

Supply Type and Insulation

Unit uses single-phase supply with Class II double insulation, requiring no earth connection.

External Switch and Wiring

A 3mm All Pole switch is required; connect cable via entry (4) using applicable diagrams.

SILENT CHZ DESIGN Features and Configuration

Humidistat and Timer Functionality

Models feature adjustable humidistat (60-90% RH) and timer (1-30 min) for automatic operation.

Dip-Switch Settings

Eight dip-switches on the PCB control functions like interval, timer, and humidistat settings.

Dip-Switch Functionality Explained

Interval Function Control (Switch 1)

Selects the 'Interval' function to manage fan operation duration in specific conditions.

Time Setting Switches (2 & 3)

Configures interval time settings between 4, 8, 12, and 24 hours.

Humidistat Setting Switches (4 & 5)

Adjusts relative humidity levels from 60% to 90% HR for automatic activation.

Over-run Timer Setting Switches (6 & 7)

Sets the fan's run-on time from 1, 5, 15, or 30 minutes after activation ceases.

Start-up Timer Function (Switch 8)

Enables or disables the start-up timer function for delayed fan activation.

Automatic Operation Modes

Two-Wire Automatic Operation

Humidistat automatically controls the fan based on humidity, with a set over-run timer.

Interval Function Operation

Manages fan operation in very wet conditions or prolonged high humidity, preventing continuous running.

Three-Wire Override Operation

Allows external switch override of humidistat; automatic mode takes precedence if humidity is high.

Start-up Timer Function

Start-up Timer Explanation

Delays extractor start-up by 50 seconds to prevent activation for very short usage periods.

Operating Scenarios and Default Settings

Specific Operating Scenario

Fan behavior described when usage exceeds 50s and humidity is below set level with light switch off.

Default Factory Settings

Lists default factory configurations for interval function, time, humidistat, and timers.

SILENT-100 CHZ DESIGN 12 V Information

12 V Model Diagram Reference

Refers to diagrams (Fig.6) and (Fig.7) for the specific SILENT-100 CHZ DESIGN 12V model.

User Information and Safety Guidelines

Manual Access and User Responsibility

Manuals available online; guidance for use by children and persons with reduced capabilities.

Appliance Safety and Supervision

Children (8+) and persons with reduced capabilities require supervision during use.

Maintenance and Service Information

Routine Cleaning Instructions

Periodical cleaning with a soft cloth lightly impregnated with mild detergent is required.

Service, Guarantee, and Faults

Do not tamper with parts; unauthorized tampering voids the guarantee. Contact dealer for faults.