SILENT-100 CRZ DESIGN
This model is provided with an adjustable
over-run timer. The timer allows the fan
to continue to operate for the selected
period after the switch has been turned
off (fi g.6).
Model provided with a 4 positions adjus-
table electronic timer: Fig.5 shows how
to connect the fan with timer utilising the
same switch as for the lighting circuit.
To set the timer, turn the potentiometer on
the printed circuit board as (fi g. 7).
-To reduce the “run on” time, turn
anticlockwise (min. 1 minute)
-To increase the “run on” time, turn
clockwise (max: 30 minutes).
SILENT-100 CHZ DESIGN
Models provided with an electronic
humidistat which can be adjusted from
60% to 90 % RH (relative humidity) and
with a timer, adjustable between 2 and
20 minutes.
Operation
Case 1: Automatic operation (fi g.9)
In automatic operation, the humidistat
causes the extractor to operate auto-
matically when the humidity level in the
room is higher than the set level. The
extractor will stop automatically when
the humidity drops below the selected
level and after the selected period set
on the timer.
Case 2: Automatic operation as in case 1
with the facility to override the hygrostat
by means of the light switch (fi g.8), when
the humidity level in the room is lower
than the selected level. In this case, the
extractor continues to operate for the
selected period set on the timer after the
switch light has been switched off.
ATENTION: When the humidity rate is
above the selected value, the automa-
tic option takes precedence over the
manual and the unit cannot then be
switched off using a switch.
The desired humidity level is selected
by means of a potentiometer “% Hr”
positioned on the printed circuit board
(fi g.10) and accessible once the grille (1)
has been removed.
- To increase the humidity setting turn
anticlockwise (min.60 %)
- To reduce the humidity setting turn
clockwise (max. 90 %)
To set the timer, turn the potentiometer
“t min.” on the printed circuit board
(fi g.10):
- To reduce the “run on” time, turn
anticlockwise (min. 2 minutes)
- To increase the “run on” time, turn
clockwise (max: 20 minutes).
Maintenance
The extractor fan only requires periodical
cleaning using a cloth lightly impregnated
with a soft detergent.
After Sales Service
We recommend you not to try to dis-
mantle or remove any other parts than
those mentioned as any tampering would
automatically cancel the S&P guarantee.
If you detect any fault, contact your S&P
dealer.
S&P reserves the right to alter specifi ca-
tions without notice

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the S&P SILENT-100 DESIGN Series and is the answer not in the manual?

S&P SILENT-100 DESIGN Series Specifications

General IconGeneral
ModelSILENT-100 DESIGN Series
CategoryFan
Sound Level26.5 dB(A)
Power Consumption8 W
Voltage230 V
Frequency50 Hz
IP RatingIP45
Diameter100 mm
Airflow95 m³/h