page 12
ASSEMBLY
Warning: This appliance requires
installation by a competent person.
Proper assembly is the responsibility of
the installer.
Step 7: To check that the regulator seal is
correctly fitted and able to fulfill its function.
Fit the LPG Cylinder into the chamber
taking care not to damage the hose or gas
system. Close gas chamber door. Use a
LPG Cylinder that is at least 80% (4/5ths)
full.
Step 8: Check for leaks
Your Outdoor Patio Heater has been
checked for leaks at all the factory made
connections. To check the connection of the
gas hose/regulator/LPG cylinder.
1) Make leak test solution by mixing 1 part
washing up liquid and 3 parts water.
2) Spoon several drops (or use squirt
bottle) of the solution onto the gas
hose/regulator and regulator/LPG
cylinder connection.
3) Inspect the connections and look for
bubbles.
4) If no bubbles appear, the connection is
safe.
5) If bubbles appear, there is leak, loosen
and re-tighten this connection.