ADJUSTMENTS
1.
Setting
the
service
mode
(1)
(2)
(3)
(4)
Disconnect
the
AC
power
plug
from
the
unit.
Press
the
PLAY/PAUSE
key
or
the
MEMORY
key
due
to
discharge
C904
connected
to
pin
18
of
1C
501
(RESET)
and
the
+V_
IN
smoothing
capacitor
(C951).
Consequently,
pin
18
of
IC
501
becomes
“LOW”.
Ground
the
pattern
of
TP36
(see
wiring
diagram
of
page
38
~
39)
using
jumper
wire.
Two
kind
of
IC
is
used
as
!C501
in
this
unit.
Follow
step
according
to
the
particular
part
No,
concerned.
TMP47C420AF8172Z
...Connect
the
AC
power
plug.
(This
mean
is
not
operation
of
the
power
switch
ON/OFF)
TMP47C420AF8173Z
°°
.Connect
the
AC
power
plug
while
pressing
the
PLAY
key.
The
player
will
be
in
the
service
mode
and
the
LCD
displays
«
Og
og
00”
2.
Particular
operation
in
service
mode
(1)
(2)
(3)
(4)
When
the
SKIP/SEARCH
key
is
pressed,
the
pickup
moves
to
the
outermost
or
innermost
portion
of
the
disc.
This
enables
to
check
the
operation
of
the
sled
motor.
When
the
MEMORY
key
is
pressed,
the
pickup
perform
a
focus
search.
If
a
disc
is
loaded
in
the
unit,
the
focus
servo
will
go
“ON”.
If
a
disc
is
not
loaded,
the
focus
search
will
take
place
indefinitely.
When
the
REPEAT
key
is
pressed
in
the
condition
of
step
2,
the
tracking
servo
will
go
“ON”,
and
the
unit
will
go
into
a
play
condition.
When
the
STOP
key
is
pressed
at
any
operating
mode,
you
can
cancel
the
ongoing
operation.
3.
Cancelling
service
mode
Disconnect
the
AC
power
plug.
and
then
remove
the
jumper
wire
from
the
pattern
of
TP36.
(See
the
wiring
diagram
of
page
38
~
39.)
Tracking
balance
adjustment
Test
disc
;
YEDS
18
(Sony)
Measuring
equipment
;
Oscilloscope
Connection
point
;
TP-3
Adjustment
point
Adjustment
value
;
a
b
SVR
-
101
Waveform
symmetry
Put
the
unit
in
the
service
mode.
Load
the
test
disc
and
then
press
the
MEMORY
key.
The
disc
will
rotate
and
the
focus
servo
will
go
ON,
Note:
!f
the
pickup
is
at
the
innermost
track,
first
press
the
PP
key
to
move
the
pickup
slightly
to
the
outside
and
not
to
play
the
TOC
(zero
pattern)
on
the
disc.
Observe
the
tracking
error
signal
(
from
TP3
)
on
the
oscilloscope
and
adjust
SVR101
so
that
the
waveform
becomes
symmetrical
with
respect
to
0
V.
(See
Fig.
1.)
Focus
offset
adjustment
Test
disc
;
YEDS
18
(Sony)
Measuring
equipment
;
Oscilloscope
Connection
point
;
TP-2
(FE-Signal)
TP
-
1
(RF-Signal)
Adjustment
point
;
SVR102
SVR
102
Adjustment
value
:
o
when
unit
in
STOP
status
Connect
the
oscilloscope
to
TP2
(FE
signal).
Connect
the
oscilloscope
to
TP1
(RF
signal).
Follow
steps
(a)
and
(b)
of
the
“Tracking
balance
adjustment”
to
turn
the
focus
servo
“ON”,
Press
the
REPEAT
key,
The
tracking
servo
will
go
ON,
and
the
player
will
be
in
a
play
condition.
Measure
the
DC
offset
voltage
of
the
waveform
[focus
error
signal
from
TP2]
using
a
DC
voltmeter,
and
note
the
measured
value.
Press
the
STOP
key
and
remove
the
disc.
Adjust
SVR102
so
that
the
DC
offset
voltage
at
TP2
becomes
the
same
as
the
voltage
measured
in
step
(e).
Re-load
the
disc,
and
then
follow
the
steps
(c)
and
(d)
to
put
the
unit
in
a
play
condition.
(MEMORY
key
“ON”
>
REPEAT
key
“ON”.)
Confirm
that
the
‘a’
portion
of
the
waveform
(RF
signal)
from
TP1
must
be
a
straight
line,
and
the
‘b’
portion
(eye
pattern)
must
be
open.
(See
Fig.
2).
Also,
verify
that
the
height
of
the
wave
is
maximum,
OPENING
EXPANDED
Ao—
Fig.
2
a
(
Voltage
when
unit
in
PLAY
=
Voltage