Recording settings (User level: ID3)
English 31
5 PRE-ALARM RECORDING
Allows you to set the pre-alarm recording operation
mode.
ON: Activates pre-alarm recording.
OFF: Pre-alarm recording is not activated.
A REC RATE (Initial setting: 12.5 FPS)
It allows you to set the pre-alarm recording rate.
Available settings:
25, 16.67, 12.5, 8.333, 6.25, 5, 4.167, 3.571, 3.125, 2.778,
2.5, 2.273, 1.923, 1.667, 1.471, 1.316, 1.19, 1.087, 1
(Unit: FPS)
B DURATION (Initial setting: 1 MIN)
To set the duration of the pre-alarm recording.
Available settings:
3, 5, 10, 20, 40 SEC, 1, 2, 3, 4, 5, 10, 15 MIN
6 ALARM TRIGGER (Initial setting: ALARM)
It allows you to set under what conditions the alarm
recording is triggered.
Selections:
ALARM (External alarm):
When an alarm signal is input to the alarm input
terminal at the rear of the DVR
SENSOR (Motion sensor):
When the motion sensor detects movement
ALARM AND SENSOR:
When both the external alarm and the motion sensor
are triggered at the same time
ALARM OR SENSOR:
When either the external alarm or the motion sensor
is triggered
7 Number of alarm recordings
Clicking [SAVE], displays, for your reference, the number
of alarm recordings that can be recorded according to
the set conditions.
F
ALARM REC MODE SET (Continued)
If the alarm recording operation mode is set to
"OFF", "***" is displayed and pre-alarm
recording cannot be set.