14-5.
BUZZER
CIRCUIT
CPU
generates
a
buzzer
drive
signal,
of
which
frequency
is
1700
Hz
and
output
it.
<
v
3
z8
Qo
3917
w3SZZN8
|
14-6.
DRAWER
/
PAPER
WINDER
STAMP
CIRCUIT
STAMP
IN
IC5
LB1235
STP
RWD
DRA
©
RWD
signal
from
|C1-55pin
(Stay
down
the
PF
key)
5v
-
14-7.
PRINTER
CIRCUIT
CHARACTER
SELECTIVE
CIRCUIT
When
the
print
command
signal
PS
is
supplied
from
58
pin
of
IC1,
the
Q7
is
enable
to
turn
on.
At
the
same
time,
the
character
selective
signal
H1
~
H13
are
supplied
and
each
character
selective
magnet
will
set
the
character
to
its
print
position.
3,4
Ht
MOTOR
DRIVE
CIRCUIT
@
26—
The
printer
motor
control
signal
PM
is
supplied
from
the
7
pin
of
IC1
as
active
High-level.
The
transistor
Q5
is
turned
on
by
the
PM
signal,
then
the
base
voltage
of
Q5
goes
low
through
the
diode
D33
and
Q5
turned
OFF.
When
Q5
is
off,
the
motor
drive
transistor
Q2
is
turned
ON,
and
the
motor
starts
rotating.
If
the
motor
voltage
is
going
to
over
the
rated
value,
the
over
current
is
supplied
to
the
base
of
Q6
through
the
zener
diode
ZD5.
When
Q6
is
ON,
the
Q4
is
going
to
OFF,
then
Q2
is
turned
to
OFF.
When
the
Q2
is
OFF,
the
motor
voltage
is
getting
decreased
to
the
specified
value,
which
is
mainly
fixed
by
the
zener
voltage
of
ZDS5.
When
the
motor
voltage
is
getting
under
the
specified
value,
the
transistor
Q2
is
turned
ON
again
and
repeated
the
cycle@~®@.
This
feed-
back
loop
makes
to
regurate
the
motor
voltage
for
the
security.
The
capacitor
C24
is
installed
as
to
avoid
the
deviation
of
this
feed-back
loop.
The
diode
D382
is
an
spike
voltage
killer.
When
the
printer
motor
control
signal
PM
is
turned
OFF
from
the
IC1,
the
Q5
becomes
OFF
and
Q2
is
turned
OFF.
When
Q2
is
OFF,
the
base
voltage
of
Q3
is
getting
High
by
R29
and
Q3
is
turned
ON.
When
Q3
is
ON,
this
transistor
lose
the
electricity
generated
in
the
motor
itself
to
the
ground
rapidly.
And
the
motor
stop
rotating.
Q4
A1528
D1825