-11-
Figure 11
Box wrench
Parts base
Blower motor
Duct for
magnetron
Magnetron bracket
Magnetron
Thermal protector
Ceramic resistor
G.HOW TO RESET THE MEMORY OF
ACCUMULATIVE COOKING TIME
Note:Total number of door operation can not be
cleared.
When new magnetron is replaced, accumulative cook-
ing time must be set “Zero” as follows.
(1) Touch “C” key. The “0” appears in the display.
(2) Touch “Clock mark” key. The colon and power level
“10” bar will appear in the display.
(3) Touch number “8” three times. The “8.88” will appear
in the display.
(4) Continuously touch course key “1”. “88.81” will
appear in the display.
(5) Touch “Start” key. All four digit will be flashing.
(6) Touch “Start ” key again. The displayed number
shows the accumulative cooking time.
(7) Touch “0” and “Memory” key.
Accumulative cooking time will be cleared.
HINT FOR LAMP CHANGE
Before removing the bulb access panel, pull out
the main-plug. Change the faulty bulb and secure
the bulb access panel. Plug the cord back in and
check operation.
H.CHANGING POWER SUPPLY CORD
For EM-C1100SD
(See exploded view on page 18)
(1) Unfasten 1 screw for ground and pull out the
2 wires of the power cord from the noise filter.
(2) Remove 1 screw for the bottom plate of the
cord bushing.
(3) Install the new power supply cord with the
reverse procedure of above (1) to (2).
WARNING:
For changing the power supply cord, never use
other than the following.
Key No. Order No. Parts name
13 617 140 1332 Cord bush
14 617 140 1349 Bottom bracket
17 617 234 0913 Cord Assembly
I.REMOVING CERAMIC TRAY
(See Figure 12)
(1) Take off the cabinet.
(2) Put (insert) a screwdriver in the 9 mmm diameter
hole located at the left back side of the cavity.
Push the tray up with the screwdriver.
(3) Open the door and take out the tray very care-
fully.
Figure 12
Screwdriver
Hole