B. TROUBLESHOOTING
STEP
SEQUENCE
RESULT
(1) PROBLEM
No display or mis-display in
the display window by touching
the keys.
a
Check 230V AC power
supply of connector S1
between Pin3 and Pin 5
after removing connector
S1 from control circuit
board.
Check continuity of FUSE,
Thermal Protector for cavity,
Thermal Protector for
magnetron and AC Power
Cord.
If the fuse has blown see
"D. REMOVING FUSE" on
page 13
0 230
0 Volt
0 230
230 Volt
PROBLEM
1-b
Control
Circuit Board
Check power supply voltage
on control circuit board.
(See page 7 )
Voltage
incorrect
Replace it if
necessary
0 V
0
V
Each Voltage
OK
Normal control
circuit board
Replace control
circuit board.
b
Runs
Runs
Correct seating of
connector S101 or
replace control circuit
board.
Normal control
circuit board
Runs
1
0
0
1
5
0
4
5
0
7
0
0
8
5
0
A
u
t
o
S
t
a
r
t
D
e
f
.
T
i
m
e
1
0
0
0
-9-
E
M
-S350
-9-