3-13
3. Y/C CIRCUIT
(4) When the Video signal doesnt appear on the screen in REC Mode,
Is the EE signal normal?
Is 5.2VT/5.3VA applied to the
IC301 Pins24,42,55,72,91?
Does the RF signal appear
at the IC301 Pin78?
Check EE Mode.
Check the System of REC
H. (the IC501 Pin47
/ the D301)
Replace the IC301.
Check the line of the 5.2VT/
5.3VA Line.(Power Circuit)
Check PB Mode.
Is the REC H signal
(about 4V) applied to the
IC301 Pin80?
Check the circuit of the
IC301 Pins85, 86.
Check REC Luminance
Pass & Color Pass.
Does PB Mdoe operate
normally?
Does the REC RF signal
appear at the IC301
Pins88,89,94,95?
Check the Drum &
Drum Connector
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO