1-5
SERVICE INFORMATION FOR EEPROM IC SETTING
MODEL NAME HEX BINARY
HV-DX1EV FC 00 00000000
61 00 00000000
89 00 00000000
E1 00 00000000
31 00 00000000
08 00 00000000
HV-DX1SP FC 00 00000000
61 00 00000000
89 00 00000000
F1 00 00000000
54 00 00000000
08 00 00000000
HV-DX1E BC 00 00000000
61 00 00000000
80 00 00000000
F3 00 00000000
D0 00 00000000
03 00 00000000
WR : OK I : EXIT MOVE :
F G
EDIT : DE
1. DETECT NEW EEPROM (OPTION EDIT
SCREEN)
- Eeprom EDIT screen automatically appears if
replacing Eeprom.
- Setup option data using the cursor Up/Down key
of a remote control.
(Setup upon BOM depending on OPT1~OPT6
model)
• Since an initial remote control is set to LG for LG
model, appropriately set optiona data using the
cursor Up/Down key.
• For SANYO model, change a remocon key by
using following JIG key.
SANYO MODEL : FRONT DVD/VCR + FRONT
CH UP (LG/SANYO CODE)
2. EEPROM WRITED COMPLETE SCREEN
- Writes data on EEPROM by using REMOCON
"OK".
- If completing the option data screen with a menu
key, Powering Off is automatically done and the
option edit screen is arranged.
3. PG ADJUST
- Plays PAL SP TAPE for adjusting the AUTO PG.
- A 0:00:00 is played in the field if pressing the
front play with Remocon number "1" key played
during PAL SP.
- The 0:00:00 in the field represents position of the
TRACKING PRESET.
- "OFF" is displayed in the field if pressing the front
play key with the remocon number "1" in the sta-
tus of the tracking preset pressed, and "ON" is
displayed in the field if AUTO PG operation is
automatically performed and completed.
- DECK STOP > plays if above operation is com-
pleted. Set operation is performed depending on
changed PG values. These values are stored in
the EEPROM area.
4. EEPROM INITIAL
- SETUP is displayed in the field if pressing the
FRONT REC KEY with the remocon number
"CLEAR" key pressed in the status of powering
Off.
- AUTO SEARCH is done since the initial screen
of ACMS is serviced if powering On.
- Check basic operation (PLAY/RECORD...)
EEPROM option code No. setting EEPROM option code No. setting procedure
NAME HEX BINARY
OPT1 00 00000000
OPT2 00 00000000
OPT3 00 00000000
OPT4 00 00000000
OPT5 00 00000000
OPT6 00 00000000
WR : OK I : EXIT MOVE :
F G
EDIT : DE
MASKROM : R00
EEPROM : R00 LG CODE