PDG-DXL100 Condential
5-14
3. Choose 8051 le (*.hex)
- "Manley Nlink" picture will appear on the
screen.
- Ensure "MCU" is the one you chose in the
last step (as green square).
- Click "Open".
- Select the 8051 le where you put the le
in, then click "Open".
4. Program settings
- Ensure NLlNK Fixture and PC are
securely connected: the indicator lights on
green, and the state is "Connect" (as
blue square).
- Select "4MHz-20MHz Crystal" and
"Brownout detect voltage is 3.8"
(as green square).
- Click "Erase/Write(W)" (as red ellipse) to
execute 8051 FW upgrade.
5. Finish
- When 8051 FW upgrade process is
nished, "Write Chip success" will be
shown (as red square).
6. Check 8051 FW version
- Turn on the unit and get into the service
mode to check the 8051 FW version.
(To get into Service mode, please press
"Power", "Enter", "Enter" and "Menu" buttons
sequentially.)