-84-
Electrical Adjustment
Grp / No. Item Function Range Initial Note
10 Filter 2nd Cartridge Scroll Time 1
2nd Filter Cartridge Used time at N times Scrolling [hour] (N:1-10)
0 - 32767 9999
11 Filter 2nd Cartridge Scroll Time 2 0 - 32767 9999
12 Filter 2nd Cartridge Scroll Time 3 0 - 32767 9999
13 Filter 2nd Cartridge Scroll Time 4 0 - 32767 9999
14 Filter 2nd Cartridge Scroll Time 5 0 - 32767 9999
15 Filter 2nd Cartridge Scroll Time 6 0 - 32767 9999
16 Filter 2nd Cartridge Scroll Time 7 0 - 32767 9999
17 Filter 2nd Cartridge Scroll Time 8 0 - 32767 9999
18 Filter 2nd Cartridge Scroll Time 9 0 - 32767 9999
19 Filter 2nd Cartridge Scroll Time 10 0 - 32767 9999
20 Filter 3rd Cartridge Scroll Time 1
3rd Filter Cartridge Used time at N times Scrolling [hour] (N:1-10)
0 - 32767 9999
21 Filter 3rd Cartridge Scroll Time 2 0 - 32767 9999
22 Filter 3rd Cartridge Scroll Time 3 0 - 32767 9999
23 Filter 3rd Cartridge Scroll Time 4 0 - 32767 9999
24 Filter 3rd Cartridge Scroll Time 5 0 - 32767 9999
25 Filter 3rd Cartridge Scroll Time 6 0 - 32767 9999
26 Filter 3rd Cartridge Scroll Time 7 0 - 32767 9999
27 Filter 3rd Cartridge Scroll Time 8 0 - 32767 9999
28 Filter 3rd Cartridge Scroll Time 9 0 - 32767 9999
29 Filter 3rd Cartridge Scroll Time 10 0 - 32767 9999
248 Filter Scroll Factor (Read only)
0 Filter 1st Cartridge Scroll Factor 1
1st Filter Cartridge Scrolling Factor at N times Scrolling (N:1-10)
0: Manual Scrolling with OSD Menu
1: Auto Scrolling detecting by Filter Clogged
2: Auto Scrolling detecting by specified maximum used time per
a sheet
0 - 255 255
1 Filter 1st Cartridge Scroll Factor 2 0 - 255 255
2 Filter 1st Cartridge Scroll Factor 3 0 - 255 255
3 Filter 1st Cartridge Scroll Factor 4 0 - 255 255
4 Filter 1st Cartridge Scroll Factor 5 0 - 255 255
5 Filter 1st Cartridge Scroll Factor 6 0 - 255 255
6 Filter 1st Cartridge Scroll Factor 7 0 - 255 255
7 Filter 1st Cartridge Scroll Factor 8 0 - 255 255
8 Filter 1st Cartridge Scroll Factor 9 0 - 255 255
9 Filter 1st Cartridge Scroll Factor 10 0 - 255 255
10 Filter 2nd Cartridge Scroll Factor 1
2nd Filter Cartridge Scrolling Factor at N times Scrolling (N:1-10)
0: Manual Scrolling with OSD Menu
1: Auto Scrolling detecting by Filter Clogged
2: Auto Scrolling detecting by specified maximum used time per
a sheet
0 - 255 255
11 Filter 2nd Cartridge Scroll Factor 2 0 - 255 255
12 Filter 2nd Cartridge Scroll Factor 3 0 - 255 255
13 Filter 2nd Cartridge Scroll Factor 4 0 - 255 255
14 Filter 2nd Cartridge Scroll Factor 5 0 - 255 255
15 Filter 2nd Cartridge Scroll Factor 6 0 - 255 255
16 Filter 2nd Cartridge Scroll Factor 7 0 - 255 255
17 Filter 2nd Cartridge Scroll Factor 8 0 - 255 255
18 Filter 2nd Cartridge Scroll Factor 9 0 - 255 255
19
Filter 2nd Cartridge Scroll Factor 10
0 - 255 255
20 Filter 3rd Cartridge Scroll Factor 1
3rd Filter Cartridge Scrolling Factor at N times Scrolling (N:1-10)
0: Manual Scrolling with OSD Menu
1: Auto Scrolling detecting by Filter Clogged
2: Auto Scrolling detecting by specified maximum used time per
a sheet
0 - 255 255
21 Filter 3rd Cartridge Scroll Factor 2 0 - 255 255
22 Filter 3rd Cartridge Scroll Factor 3 0 - 255 255
23 Filter 3rd Cartridge Scroll Factor 4 0 - 255 255
24 Filter 3rd Cartridge Scroll Factor 5 0 - 255 255
25 Filter 3rd Cartridge Scroll Factor 6 0 - 255 255
26 Filter 3rd Cartridge Scroll Factor 7 0 - 255 255
27 Filter 3rd Cartridge Scroll Factor 8 0 - 255 255
28 Filter 3rd Cartridge Scroll Factor 9 0 - 255 255
29
Filter 3rd Cartridge Scroll Factor 10
0 - 255 255
249 Pressure Sensor
0 Pressure Monitor Pressure Sensor Value [ADC] (Read only) - -
1 Pressure Monitor Pressure Sensor Value with Compensate [ADC] (Read only) - -
2 Presss Offset Offset Value - 1023 - 1023 0
3 Press calib Effective Diff Effective Range [ADC] 0 -123 1023
4 Press Sensor Calibration Log
0: Executed & Normal Range (Read ony)
10: Out of Range Minimum
20: Out of Range Maximum
99: Not execute Calibration
- 99
250 Fan Voltage Adjustment