Electrical Adjustment
Grp / No. Item Function Range Initial Note
0 Fan 1 Min Adjust (DAC)
DAC Output for Fan Voltage adj.
Adjust Tolerance between DAC and Fan Volt.
*Lamp Mode: Eco
0 - 255 39
1 Fan 1 Max Adjust (DAC) 0 - 255 212
2 Fan 2 Min Adjust (DAC) 0 - 255 50
3 Fan 2 Max Adjust (DAC) 0 - 255 218
4 Fan 3 Min Adjust (DAC) 0 - 255 82
5 Fan 3 Max Adjust (DAC) 0 - 255 213
6 Fan 4 Min Adjust (DAC) 0 - 255 64
7 Fan 4 Max Adjust (DAC) 0 - 255 211
8 Fan 5 Miin Adjust (DAC) 0 - 255 65
9 Fan 5 Max Adjust (DAC) 0 - 255 211
10 Fan 5 Miin Adjust (DAC) 0 - 255 28
11 Fan 5 Max Adjust (DAC) 0 - 255 211
252 Fan Option
1 Safety Switch Safety Application use 0 - 8 0
2 Fan Manual Switch Fan Manual SW (0: Auto 1: Manual) 0 - 1 0
3 Fan 1 Manual Voltage
Manual Adjustment Mode (0.1V)
*Effective only when Manual SW is 1.
0 - 255 100
4 Fan 2 Manual Voltage 0 - 255 100
5 Fan 3 Manual Voltage 0 - 255 100
6 Fan 4 Manual Voltage 0 - 255 100
7 Fan 5 Manual Voltage 0 - 255 100
8 Fan 6 Manual Voltage 0 - 255 100
- -
253 Fan Temp Error Setting (Memorized) Normal Ceiling Top Bottom
0 Temp A Warning Temp A (Room) to judge the Temp Error 30 - 100 44 44 44 44
1 Temp C-A Warnin Temp C-A (Panel - Room) to judge the Temp Error 0 - 100 20 20 20 20
254 Fan Control Range Setting (Temp/Voltage) Normal Ceiling Top Bottom
0 Normal Fan Control Min Temp
Temp Sensor Control Start/End Temp at Normal
20 - 100 27 27 27 27
1 Normal Fan Control Max Temp 20 - 100 42 42 42 42
2 Normal Fan 1 Min
Fan Voltage Set at Normal (Min/Max) (x0.1V)
0 - 255 60 60 60 60
3 Normal Fan 1 Max 0 - 255 132 132 132 132
4 Normal Fan 2 Min 0 - 255 85 85 85 85
5 Normal Fan 2 Max 0 - 255 135 135 135 135
6 Normal Fan 3 Min 0 - 255 80 80 80 80
7 Normal Fan 3 Max 0 - 255 132 132 132 132
8 Normal Fan 4 Min 0 - 255 115 115 105 105
9 Normal Fan 4 Max 0 - 255 115 115 105 105
10 Normal Fan 5 Min 0 - 255 115 115 105 105
11 Normal Fan 5 Max 0 - 255 115 115 105 105
12 Normal Fan 6 Min 0 - 255 70 70 70 70
13 Normal Fan 6 Max 0 - 255 132 132 132 132
14 Eco Fan Control Min Temp
Temp Sensor Control Start/End Temp at Eco
20 - 100 27 27 27 27
15 Eco Fan Control Max Temp 20 - 100 42 42 42 42
16 Eco Fan 1 Min
Fan Voltage Set at Eco (Min/Max) (x0.1V)
0 - 255 50 50 50 50
17 Eco Fan 1 Max 0 - 255 120 120 120 120
18 Eco Fan 2 Min 0 - 255 55 55 55 55
19 Eco Fan 2 Max 0 - 255 125 125 125 125
20 Eco Fan 3 Min 0 - 255 70 70 70 70
21 Eco Fan 3 Max 0 - 255 125 125 125 125
22 Eco Fan 4 Min 0 - 255 80 80 70 70
23 Eco Fan 4 Max 0 - 255 80 80 70 70
24 Eco Fan 5 Min 0 - 255 80 80 70 70
25 Eco Fan 5 Max 0 - 255 80 80 70 70
26 Eco Fan 6 Min 0 - 255 55 55 55 55
27 Eco Fan 6 Max 0 - 255 125 125 125 125
255 Fan Start/Cooling Setting
0 Fan 1 Initial Volt
Fan Start Voltage (x0.1V)
0 - 255 50
1 Fan 2 Initial Volt 0 - 255 75
2 Fan 3 Initial Volt 0 - 255 70
3 Fan 4 Initial Volt 0 - 255 80
4 Fan 5 Initial Volt 0 - 255 80
5 Fan 6 Inital Volt 0 - 255 55
6 Cooling Time Cooling Time Setting (x30 sec.) 1: 30 3: 90 15: 450 1-15 3
8 Temp Error Cooling Time
Cooling Time Setting When the Temp Error occurs (x30 sec.)
1: 30 3: 90 15: 450
1-15 3
9 OnStart Cooling Start Threshold 0-100 38
10 After shutdown cooling Cooling Operation after Shut Down (0: No, 1: Yes) 0-1 1