-60-
Electrical Adjustment
Grp / No. Item Function Range Initial Note
18 Normal Fan1 Min
Fan Spinning Set at Normal (Min/Max) (0.1V)
0000-9990 120 120 120 120
19 Normal Fan1 Max 0000-9990 138 138 138 138
20 Normal Fan2 Min 0000-9990 90 90 115 115
21 Normal Fan2 Max 0000-9990 90 90 115 115
22 Normal Fan3,4 Min 0000-9990 70 70 70 70
23 Normal Fan3,4 Max 0000-9990 138 138 138 138
24 Normal Fan5 Min 0000-9990 95 95 95 95
25 Normal Fan5 Max 0000-9990 138 138 138 138
26 Normal Fan6 Min 0000-9990 60 60 60 60
27 Normal Fan6 Max 0000-9990 138 138 138 138
28 Normal Fan7 Min 0000-9990 65 65 65 65
29 Normal Fan7 Max 0000-9990 138 138 138 138
30 Normal Fan8 Min 0000-9990 80 80 80 80
31 Normal Fan8 Max 0000-9990 138 138 138 138
32 Eco Fan Control Min Temp
Temp Sensor Control Start/End Temp St Eco
20-100 31 31 31 31
33 Eco Fan Control Max Temp 20-100 38 38 38 38
34 Eco Fan1 Min
Fan Spinning Set at Eco (Min/Max) (0.1V)
0000-9990 110 110 110 110
35 Eco Fan1 Max 0000-9990 110 110 110 110
36 Eco Fan2 Min 0000-9990 138 138 138 138
37 Eco Fan2 Max 0000-9990 60 60 70 70
38 Eco Fan3,4 Min 0000-9990 55 55 55 55
39 Eco Fan3,4 Max 0000-9990 138 138 138 138
40 Eco Fan5 Min 0000-9990 75 75 75 75
41 Eco Fan5 Max 0000-9990 138 138 138 138
42 Eco Fan6 Min 0000-9990 50 50 50 50
43 Eco Fan6 Max 0000-9990 138 138 138 138
44 Eco Fan7 Min 0000-9990 50 50 50 50
45 Eco Fan7 Max 0000-9990 138 138 138 138
46 Eco Fan8 Min 0000-9990 70 70 70 70
47 Eco Fan8 Max 0000-9990 138 138 138 138
255 Fan Start/Cooling Setting
0 Fan1 Initial Volt
Fan Start Voltage (0.1V)
0-255 70
1 Fan2 Initial Volt 0-255 70
2 Fan3,4 Initial Volt 0-255 70
3 Fan5 Initial Volt 0-255 70
4 Fan6 Initial Volt 0-255 70
5 Fan7 Initial Volt 0-255 70
6 Fan8 Initial Volt 0-255 70
8 Cooling Time Coolong Time Setting (x30 sec.) 1: 30 3: 90 15: 450 1-15 3
10 Temp Error Cooling Time
Cooling Time Setting When the Temp Error occurs (x30 sec.)
1: 30 3: 90 15: 450
1-15 3
11 OnStart Cooling Start Threshold 0-100 50
12 After shutdown cooling Cooling Operation after Shut Down (0: No, 1: Yes) 0-1 1
13 Normal Fan2 Cooling Voltage Cooling Fan Voltage of Fan2 at Normal x0.1V 0 - 255 50 50 50 50
14 Eco Fan2 Cooling Voltage Cooling Fan Voltage of Fan2 at Eco x0.1V 0 - 255 50 50 50 50
259 Fan Air Pressure Setting
0 Press Source Range Low Pressure Sensor Control Range (AD) 0-1024 637
1 Press Source Range High 0-1024 293
2 Press Fan Add Range High Add Voltage (0.1V) 0 - 2000 0
3 Press Fan Add Range Low 0 - 2000 65
4 Temp C-A Upward High Temp C-A Upward High 0 - 1000 31
5 Temp C-A Upward Low Temp C-A Upward Low 0 - 1000 29
6 Temp C-A Downward High Temp C-A Downward High 0 - 1000 20
7 Temp C-A Downward Low Temp C-A Downward Low 0 - 1000 16
260 Auto Calibration (Common) * Auto calibration
0 Execute Calibration
Execute Calibration when the Value is changed. (For PC White
100%)
0 - 1 0
1 Loop Count Max Times of Calibration 1 - 30 8
2 Auto Status
Calibration Log (Read only)
0: Calibration End Correctly 1: On Adjusting 9: Calibration
Error
0 / 1 / 9 0
3 AutoWait Waiting time 1 - 20 3
4 CHECK - Tolerance Tolerance of Offset 1 - 255 4
5 Time out wait Wait Time until Time out [sec.] 1 - 255 20
261 Auto Calibration (RGB) PW392-AFE MDL <10bits>