1. Remove the Retaining ring(ER-type) by leaving it against the adjustable foot with slot screwdriver.
2. Turn the adjustable feet and to take from the Cabinet bottom off. (2 places)
3. Remove 20 screws and remove the Handles.
(See Fig.9-2, 9-2a)
9-2
Rear adjustable feet and Handles removal.
Mechanical Disassemblies
Retaining
Ring
Adjustable foot
(Rear)
Adjustable foot
(Rear)
Adjustable feet
Adjustable foot
(Rear)
Handle
Handle
Slot screwdriver
(2 Places)
Sheet-A
Sheet-B
Sheet-C
Shield Plate-A
Shield Plate-C
Shield Plate-B
9-3
Shield plates and Sheets removal.
1. Remove the shield plates and sheets from the cabinet bottom.
(Shield plates are bent and attached in the cabinet bottom.)