- 25 -
Mechanical disassemblies
A
A
A
A
B
5-1
Switch Power Supply(25V) unit removal.
1. Remove 4 screws-A, remove screw-B and remove the Switch power supply (25V) unit.
5-2
Switch Power Supply(25V) unit disassemblies.
1. Remove 2 screws-A and remove the Switch power supply (25V) Board.
2. Unhook the 4 Fixer Clamps and remove the Motor &Audio Board.
3. Remove 2 screws-B and remove the F-G net Board.
4. Remove 3 screws-C and remove the grounding leads.
A
A
B
B
C
C
C
Switch Power supply (25V) Unit
Switch Power supply
(25V) Board
Grounding Lead
Grounding Lead
Grounding Lead
F-G Net Board
Motor Board
The Motor Board is fixed with
holder by hook.