- 30 -
5-6
1. Unhook the part(a) and remove the current sensor.
Note:The way of installing a current sensor is very important on the performance and the safety. Install in the
condition which is the same as the time of disassemble.
Replacement
1. The Current sensor is attached in the blue lead wire between a noise filter (LF901) and power unit (K6A).
2. The Current sensor (L) side is attached in the K6A side.
Refer to schematic diagrams.
PWB board may be reassembled in the same location and direction from which they were removed. Be careful of the attached
direction of PWB board.
Power Unit removal.
Power Unit removal.
1. Remove 2 screws-A, remove 2 screws-B and remove the Power Unit.
2. Remove 4 screws-C and remove the Power Board.
Mechanical disassemblies
Current sensor replacement
Blue lead wire
Current sensor
(A903)
Printed Mark
Ass'y Power unit
(A903)
K96W
Noise Filter
(LF901)
Blue lead wire
Current
sensor
Power unit
LF901
Power unit
HolderPower
Power Board