- 36 -
A
A
B
B
C
D
D
D
E
E
9-1
Ducts, R/C 2 Board, Filter Unit, NET Board and Panel removal.
1. Remove 2 screws-A and remove the Duct-D.
2. Remove 2 screws-B and remove the Duct-C.
3. Remove screw-C and remove the R/C 2 Board.
4. Pull out Air Filter Unit.
5. Remove 3 screws-D and remove the Panel.
6. Remove 2 screws-E and remove the Lens NET Board.
Mechanical disassemblies
CAUTION
Do not operate a projector with air filter removed. Dust may accumulate on LCD panel and Mirror
degrading picture quality.
Do not put small parts into air Intake Vents. It may result in malfunction of a projector.
The filter be careful and handle. The effect of the filter runs out in case of a leak and it being broken
off.
Air Filter unit
Lens net Board
Panel
Duct-D
Duct-C
R/C2 Board