Service Adjustment
Group/
Item
Item Name Function Initial Range Note
2 PJLink Enable PJLink 0 0 - 1 0: Disable 1: Enable
3 Shipping Setting 0 0 - 20 Default set when the value is set to 10
4 CABLE SW Long Cable 0 0 - 1 0: Disable, 1: Enable
5 PW Debug Command Enable 0 0 - 1
0:Disable (Serial Command Eanble)
1: Enable (PW Debug Mode)
6 Device Refresh Disable 0 0 - 1
0:Enable, 1:Disable
No last memory
7 Device Access Disable 0 0 - 1
0:Enable (Normal), 1:Disable
No last memory
20 Projector Time Reset 0 0 - 20
Projector Time is cleared when the
value is set to 10
21 Lamp Warning Time (NORMAL)
Lamp Life at Normal Mode (Warning
Time at Normal)
500 -
8000
22 Lamp Warning Time (ECO)
Lamp Life at Eco Mode (Warning
Time at Eco)
500 -
8000
30 Lamp life test enable 0:Disable 1:Enable, for safety test only
31 Lmap On time(for life test) For test purpose
32 Lamp O time(for life test) For test purpose
33 Lamp total time(for life test) For test purpose
50 Lamp Replacement Display Lamp Warning Display On / O 1 0 - 1 1: On, 0: O
51 Filter Warning Display Filter Warning Display On / O 1 0 - 1 1: On, 0: O
52 Lamp Counter reset Times Reset Times of Lamp Counter 0 0 - 255 Read only
53 Filter Counter Reset Time Reset Times of Filter Counter 0 0 - 255 Read only
54 Factory Default Execute Times Reset times of Fanctory Default 0 0 - 255 Read only
55 Motor Disable Motors Disable 0 0 - 1 0: On, 1: O
56 Menu Position Move menu (X asis) 0 0 - 1024
57 Menu Position Move menu (Y asis) 0 0 - 1024
58 Lamp Go Out n/a 0 - 1
59 Source Search Enable Source Search 0 0 - 1 0:Disable 1: Enable
70 RC Mode Setting RC Mode 0 0 - 1
0: Normal RC Mode
1: Promethean RC Mpde
71 Force Model Option Model Option Force Setting 0 0 - 2
0: Normal 1: Force for XE50 2: Force for
XL50
80 Panel life test mode Setting panel life test mode 1 0 - 1 0: Life test mode 1: Normal
Group 201 Option (signal)
0 FrameLock Option 1 0 - 1
0: FrameLockOFF at PC signal
1: FrameLockON at PC signal and 47Hz
(Vfreq) ~ Panel frequency of input
signal
2 Field Sense Invert Enable 0 0 - 1
Reverse Processing of FLDINVSetting
Value
0: Disable - Used FLDINV Setting Value
1: Enable - Used Reversed FLDINV
Setting Value
3
4 Sub Image Enable 1 0 - 1
0:Disable (Service Adjustment Dsiable,
Used all the Center Values
1:Enable (Service Adjustment Enable)
6 Zoom Accelerator Enable 0 0 - 1
0:Zoom Accelerator OFF,
1:Zoom Accelerator ON
No last memory
7 DZoom Reset by Keystone 0 0 - 1
0:Enable (Normal), 1:Disable (Dzoo
is not cancelled even if Keystone is
cancelled)
No last memory
8 Stability Count Count Value of V-missing 5 0 - 255
9
Sensivity for Signal Lost
(HSYNC)
Only used this value for No Signal
Judgement(Hz)
350
0 -
32757
10
Sensivity for Signal Lost
(VSYNC)
Only used this value for No Signal
Judgement(Line)
3 0 - 255
11 Keystone Filter Center Value Reference Value 16 0 - 30
Group 203 Option (XE50 FPGA)
0 FPGA Version FPGA Version Display Read only
1 ON / OFF
Yniformity Adjustment Setting
ON/OFF
1 0 - 1 0 : OFF 1: ON
2 MODE Table No. of FPGA 0 0 - 3 0 : TBL0, 1: TBL1 2: TBL2
3 SEL
Uniformity adjustment Method
Setting
1 0 - 1
0: Output = Input x (kH+kV) /2
1: Output = Input x (kH+kV)
4 HANTEN Adrres Reverse Setting 0 0 - 3
0 : Normal 1 : R/L reverse 2: U/D
reverse 3: R/L/U/D reverse
5 Red Gain Red Gain Setting 128/92/128/92/128 0 - 255 Normal/Red/Blue/Yellow/Green