EasyManua.ls Logo

Sanyo SAP-K161GJA - Page 38

Sanyo SAP-K161GJA
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
35
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at
220V ~ 60Hz
Rating Conditions Running Amps. A 0.42 0.60 13.48 14.5
Power Input kW 0.086 0.131 2.673 2.89
SSA 385, 386 Running Amps. 0.42 0.60 15.78 16.8
Conditions Power Input 0.086 0.131 3.173 3.39
Full Load Conditions Running Amps. A 0.42 0.60 18.98 20.0
Power Input kW 0.086 0.131 3.863 4.08
Rating Conditions : Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
SSA 385, 386 Conditions (Saudi standard)
: Indoor Air Temperature 29°C D.B. / 19°C W.B.
Outdoor Air Temperature 46°C D.B. / 24°C W.B.
Full Load Conditions : Indoor Air Temperature 29°C D.B. / 19°C W.B.
Outdoor Air Temperature 54°C D.B.
Indoor Unit SAPK241GJA SAPK241MBA
Outdoor Unit SAPC241JA SAPC241BA
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at
220 – 240V ~ 50Hz
Rating Conditions Running Amps. A 0.39 / 0.40 0.49 / 0.50 11.92 / 11.90 12.8 / 12.8
Power Input kW 0.075 / 0.080 0.106 / 0.118 2.469 / 2.562 2.65 / 2.76
Full Load Conditions Running Amps. A 0.39 / 0.40 0.49 / 0.50 16.62 / 15.90 17.5 / 16.8
Power Input kW 0.075 / 0.080 0.106 / 0.118 3.509 / 3.542 3.69 / 3.74
Rating Conditions : Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 52°C D.B.
Indoor Unit SAPK241GJA SAPK241MBA
Outdoor Unit SAPC241GA SAPC241MA

Table of Contents

Related product manuals