Sanyo SHA TM64 AGB
26 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3
Schedule Timer
Power Outages
If the air conditioner is running when power is lost, the air conditioner remains OFF when power is restored. Also, if remote con-
troller operation was disabled when power was lost, it is enabled for a few minutes when power is restored.
Programmed operations scheduled for times that come after power is restored run as usual.
Program settings are retained in the non-volatile memory of the schedule timer, therefore they are not cleared in the event of
a power outage. Also, the present time and today's day of the week are retained for a maximum of 100 hours by the internal
battery.
Schedule timer settings (Example)
Operation when power is not lost
*1 Whether remote controller operation is enabled or disabled depends on the setting of the
previous day.
Operation when power is lost at 15:00 and subsequently restored
Air conditioner
operation
Remote controller
operation
Air conditioner
operation
Remote controller
operation
*1 Whether remote controller operation is enabled or disabled depends on the setting of the
previous day.
*2 Remote controller operation is enabled for a few minutes after power is restored.
*1
8:00 12:00 17:00 20:0013:00 18:00
Stopped StoppedStopped
Running Running
Enabled
Enabled
Disabled
Disabled
Running
Stopped
*2
8:00 12:00
17:00 20:0013:00 18:00
*1
Stopped
Stopped
Stopped
Running Running
Enabled EnabledDisabled Disabled
Running
Disabled
Stopped
Power outage
Power lost here.