III - 38
Service Procedures
3
SM830063
7 SPW-CR703GVH8, SPW-CR903GVH8
FMO
4-Way valve
(20S), (WHT)
1232_D_I
TH4 (BRN)
Motor operated
valve (MOV)
TH3 (BLK)
TH5 (RED)
CR-
C703GVH
RC
52C1 52C2
1233_D_I
TH4 (BRN)
4-Way valve
(20S), (WHT)
HPV
LPV1 LPV2
LIVA LIVP
SAVE
R.S.T
49C2
R.S.T
49C1
TH2
(GRN)
TH1
(WHT)
63PH1
(WHT)
63PH2
(RED)
LPV3
7 SPW-CR703GV8, SPW-CR903GV8
FMO
1235_D_I
RC
52C1 52C2
TH3 (BLK)
TH5 (RED)
CR-
C703GV
1236_D_I
HPV
LPV1 LPV2
LIVA LIVP
SAVE
R.S.T
49C2
R.S.T
49C1
TH1
(WHT)
LPV3
TH2
(GRN)
63PH1
(WHT)
63PH2
(RED)
2. Sensor and Solenoid Layout Diagram
TH1
TH2
TH4
TH5
2
1
2
1
3
2
1
2
1
WHT
WHT
WHT
WHT
BRN
BRN
BLK
BLK
(WHT)
CN84
(GRN)
CN85
(BRN)
CN82
TH3
2
1
BLK
BLK
(BLK)
CN81
(RED)
CN80
(PC DISCHARGE GAS TEMP)
(AC DISCHARGE GAS TEMP)
(COIL LIQUID TEMP)
(COIL GAS TEMP)
(SUCTION AIR TEMP)
1234_THS_I
TH1
TH2
TH5
2
1
2
1
2
1
WHT
WHT
WHT
WHT
BLK
BLK
(WHT)
CN84
(GRN)
CN85
TH3
2
1
BLK
BLK
(BLK)
CN81
(RED)
CN80
(PC DISCHARGE GAS TEMP)
(AC DISCHARGE GAS TEMP)
(COIL LIQUID TEMP)
(SUCTION AIR TEMP)
1237_THS_I

Table of Contents