1-2. Major Component Specifi cations
(A) Indoor Units
Concealed-Duct Type SPW-UR604SH56B, U605SH, U605SHT
MODEL No.
SPW-UR604SH56B SPW-U605SH SPW-U605SHT
Source
220 - 230 - 240 V, 1 phase, 50/60 Hz
Controller P.C.B. Ass'y
CR-UXRP71B-B or CB-UXRP71B-B (Microprocessor)
Fan (Number...diameter, depth)
Centrifugal (3...ø190, L200)
Fan motor
Model...Nominal output W KFC4X-141A5P...160W KFC4X-141D5P-S...160W
Source 220 - 230 - 240 V, 1 phase, 50/60 Hz
No. of pole...rpm (230V, High) rpm 4P...1,207
Coil resistance
(Ambient temperature 20°C)
Ω
BRN–WHT : 25.79 ORG–YEL : 5.792
WHT–VLT : 5.086 YEL–BLK : 6.746
VLT–ORG : 8.626 BLK–PNK : 6.361
Safety device
Operation temperature Open °C 130 ± 5
Operation temperature Close °C (115 ± 5)
Run capacitor VAC, µF 450 VAC, 8.0 µF
Electronic expansion valve
Coil
Coil resistance (at 20°C)
Ω
Valve body
Heat Exchanger
Coil Aluminium plate fin / Copper tube
Rows...fin pitch mm 3...2.0
Face area m
2
0.308
Panel
Model No.
Dew proof heater
Auto louver motor
Coil resistance (at 20°C)
Ω
Drain Pump
ZPLD-12230ST-XH-B PLD-12230STHU-1
Rated VAC, W AC 230V, 50Hz, 12W
Total head & capacity 1200mm, 400cc/min
SM830160-03ClassicPAC-iA4.ind253253SM830160-03ClassicPAC-iA4.ind253253 2010/02/1610:26:342010/02/1610:26:34