EasyManua.ls Logo

Sanyo VHR-H792E - Service Notice on Replacing Eeprom

Sanyo VHR-H792E
91 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-5
In case that defective EEPROM of PAL models is replaced, to operate these sets from the initial state MP KEY
must be repaired as well before delivering to the customer.
If MP KEY isnt repaired the setting of RF OUT channel or LANGUAGE might be different from that for cus-
tormers country.
MP KEY : In case of PAL VCR if holding the REC button on the front panel and the CLEAR button on the
remote control handset for 5 ~ 7 seconds with power being switch all and no tapes, OK is LED
becomes on.
This is the state that initializing EEPROM is finished.
MP KEY's function : MP KEY sets EEPROM's data up to the initial state.
SERVICE NOTICE ON REPLACING EEPROM
TIMER
AM
REC
VCR
LED CLOCK MODEL:
MP KEY Switch all on a Light

Table of Contents