1-6
SERVICE INFORMATION FOR EEPROM IC SETTING
MODEL NAME HEX BINARY
VHR-M292E OPTION1 22 00000000
OPTION2 C0 00000000
OPTION3 81 00000000
OPTION4 F3 00000000
OPTION5 00 00000000
OPTION6 03 00000000
VHR-H792E OPTION1 2C 00000000
OPTION2 C3 00000000
OPTION3 89 00000000
OPTION4 F3 00000000
OPTION5 00 00000000
OPTION6 03 00000000
VHR-H802E OPTION1 BC 00000000
OPTION2 D3 00000000
OPTION3 89 00000000
OPTION4 F3 00000000
OPTION5 00 00000000
OPTION6 03 00000000
VHR-M292IR OPTION1 82 00000000
OPTION2 C1 00000000
OPTION3 89 00000000
OPTION4 F4 00000000
OPTION5 00 00000000
OPTION6 00 00000000
VHR-H792IR OPTION1 AC 00000000
OPTION2 C3 00000000
OPTION3 89 00000000
OPTION4 F4 00000000
OPTION5 00 00000000
OPTION6 00 00000000
VHR-M262EV OPTION1 02 00000000
OPTION2 C0 00000000
OPTION3 81 00000000
OPTION4 F1 00000000
OPTION5 30 00000000
OPTION6 08 00000000
VHR-M292EV OPTION1 82 00000000
OPTION2 C1 00000000
OPTION3 89 00000000
OPTION4 F1 00000000
OPTION5 30 00000000
OPTION6 08 00000000
VHR-H772EV OPTION1 AC 00000000
OPTION2 C1 00000000
OPTION3 89 00000000
OPTION4 F1 00000000
OPTION5 30 00000000
OPTION6 08 00000000
VHR-M272SP OPTION1 72 00000000
(PORTUGAL) OPTION2 C0 00000000
OPTION3 81 00000000
OPTION4 F1 00000000
OPTION5 A4 00000000
OPTION6 08 00000000
MODEL NAME HEX BINARY
VHR-H772SP OPTION1 7C 00000000
(PORTUGAL) OPTION2 C0 00000000
OPTION3 81 00000000
OPTION4 F1 00000000
OPTION5 A4 00000000
OPTION6 08 00000000
VHR-M272SP OPTION1 72 00000000
(SPAIN) OPTION2 C0 00000000
OPTION3 81 00000000
OPTION4 F1 00000000
OPTION5 50 00000000
OPTION6 08 00000000
VHR-H772SP OPTION1 7C 00000000
(SPAIN) OPTION2 C0 00000000
OPTION3 81 00000000
OPTION4 F1 00000000
OPTION5 50 00000000
OPTION6 08 00000000
WR : OK I : EXIT MOVE : F G
EDIT : DE
1. DETECT NEW EEPROM (OPTION EDIT SCREEN)
- Eeprom EDIT screen automatically appears if replacing
Eeprom.
For SANYO model, change a remocon key by using fol-
lowing JIG key.
SANYO MODEL : FRONT UP + FRONT FF
(LG/SANYO CODE)
Option Screen
→→
Change SANYO Code
→→
Service
SANYO REMOCON
- Setup option data using the cursor Up/Down key of a
remote control.
2. EEPROM WRITED COMPLETE SCREEN
- Writes data on EEPROM by using REMOCON "OK".
- If completing the option data screen with a menu key,
Powering Off is automatically done and the option edit
screen is arranged.
3. PG ADJUST
a) Insert the PAL SP Test Tape and play.
Note - Adjust the distance of X, pressing the
Tracking(+) or Tracking(-) when the “ATR” is
blink after the PAL SP Test Tape is inserted.
b) Press Front“Play” key on set and “0” key on Remocon.
(Then check the light all CLK/DOT LED on CLK/LED
- TRK is a Initial)
c) Press Front “Play” key on set and “0” key on
Remocon again.(Then check the blink “OFF → ON” on
CLK/LED, Then check the blink “PG waveform” on
oscilloscope).
4. EEPROM INITIAL
- SETUP is displayed in the field if pressing the FRONT
REC KEY with the remocon number "CLEAR" key
pressed in the status of powering Off.
- AUTO SEARCH is done since the initial screen of ACMS
is serviced if powering On.
- Check basic operation (PLAY/RECORD...)
EEPROM option code No. setting EEPROM option code No. setting procedure
NAME HEX BINARY
OPT1 00 00000000
OPT2 00 00000000
OPT3 00 00000000
OPT4 00 00000000
OPT5 00 00000000
OPT6 00 00000000
WR : OK I : EXIT MOVE : F G
EDIT : DE
MASKROM : R00
EEPROM : R00 LG CODE