INITIAL BUS DATA SETUP (Cont.)
8. Select NO. 4C RD (Red Drive) with or key. Adjust the data with + or – key for 50.
9. Select NO. 4D GD (Green Drive) with or key. Adjust the data with + or – key for 0A.
10. Select NO. 4E BD (Blue Drive) with or key. Adjust the data with + or – key for 50.
11. Select NO. 69 EWD (E/W DC) with or key. Adjust the data with + or – key for 0F.
12. Select NO. 6A EWA (E/W Amp) with or key. Adjust the data with + or – key for 0D.
13. Select NO. 6B EWT (E/W Tilt) with or key. Adjust the data with + or – key for 25.
14. Select NO. 6C ECB4ECT (E/W Bottom / E/W Top) with or key. Adjust the data with + or – key for 63.
15. Select NO. 8D HR (OSD H Position) with or key. Adjust the data with + or – key for 1E.
16. Select NO. 8E SBO (Sub Bright Offset) with or key. Adjust the data with + or – key for 05.
17 Select NO. 92 DCL (YUV Color Difference) with or key. Adjust the data with + or – key for 00.
18. Select NO. 98 DRY (YUV R-Y Difference) with or key. Adjust the data with + or – key for FD.
19. Select NO. 99 DBY (YUV B-Y Difference) with or key. Adjust the data with + or – key for FD.
20. Select NO. B1 4AVP2EWA (4:3CRT AV/Comp Pix2 East/West Amp Difference) with or key. Adjust the
data with + or – key for F9.
17. Select NO. BA 4DIGP3VBL (4:3 CRT Digital Pix3 V Blk SW) with or key. Adjust the data with + or – key for 00.
18. Press the MENU key (remote) to turn off the Service Menu display.