EasyManua.ls Logo

SANYU SY5000 Series - F4 Group: Torque Control Configuration; F4.11-F4.15 Torque Control Configuration

SANYU SY5000 Series
263 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
51
F 5.00
V/F curve set
0linear curve
1decreasing torque curve 1
1.3 power
2decreasing torque curve 2
1.5 power
3decreasing torque curve 3
1.7 power
4square curve
5 user set V/F curve
determined by F5.01F5.06
1
0
×
F 5.01
V/F frequency F1
0.00F2 (frequency value)
0.01Hz
12.50
×
F 5.02
V/F voltage V1
0.0V2 (voltage value)
0.1%
25.0%
×
F 5.03
V/F frequency F2
F1F3 (frequency value)
0.01Hz
25.00
×
F 5.04
V/F voltage V2
V1V3 (voltage value)
0.1%
50.0%
×
F 5.05
V/F frequency F3
Freq. Value F2~【F2.02rated
freq. of motor
0.01Hz
37.50
×
F 5.06
V/F voltage V3
Voltage value V2 100.0 *
F2.04rated voltage of motor
0.1%
75.0%
×
F 5.07
Torque boost setting
0.0 30.0 *rated voltage of
motorF2.04
0.1%
Depending
on model
×
F 5.08
Torque boost cutoff
point
0.00rated freq. of motor
0.01Hz
15.00
×
F 5.09
V/F control slip
frequency
compensation
0.0200.0*rated slip
note default as 100.0% in
0.1%
0.0%

Related product manuals