SANYU SY8000-011G/015P-4 - Chapter 5 Function Parameters Table; 5.1 Function Parameter Table Overview

Default Icon
50 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
35
P0.00
P0.01
P0.02
P0.03
P0.04
P0.05
P0.06
P0.07
P0.08
P0.09
P0.10
P0.11
P0.12
P0.13
P0.14
P0.15
0
0
0
0
0.0%
0.0%
0.0%
0
50.00Hz
50.00Hz
50.00Hz
0.00Hz
ABS000
ABS001
ABS002
ABS007
ABS008
ABS009
ABS010
ABS011
ABS012
ABS013
ABS014
ABS015
ABS003
ABS004
ABS005
ABS006
0.1~3600.0s
0.1~3600.0s
1.0~15.0KHZ
0.0%~50.0%
0.1~3600.0s
10.00Hz~600.00Hz
P0.15~P0.13
0.0~200.0%
◎
○
○
◎
○
○
◎
○
○
○
○
◎
○
◎
○
◎
36
Chapter 5 Function parameters table
5.1 Function parameters table
The function code adopts tertiary menu, for instance, “ P8.08” means No. 8
function code of P8 group function. PE group indicates the manufacturer's
function parameters, user has not right to access the parameters of this group.
To take convenience for the setting of function code, when operating with the
operation panel, the function group number, function code and function code
parameters are respectively corresponding to the primary menu, secondary menu
and tertiary menu.
1)The information in the column of function table is described as follows:
Column1: “Function group” that refers to PO~PE, total 16 groups;
Column2: “ Function code” that refers to the function parameter group and
parameter no.
Column 3: “Name” refers to the integral name of function parameters;
“Parameter description”refers to the expatiation of function parameters;
Column 5: “Default” refers to the ex-factory original setting value of function
parameters;
Column 6: “ Amendment” refers to the amended attribute (that is, amendment
conditions or whether the amendment is permissible), introduced as follows:
“○” represents the parameter may be amendable when the inverter is in the
shutdown and running state;
"◎"represents the parameter is unallowable to be amended when the inverter is
in the running state;
“●” represents the parameter is unallowable to be amended when it is the
actual measured and recorded value.
(The inverter has performed the self examination and limitation for the
amendment attribute of function parameters, so it can prevent user's incorrect
amendment.)
Column 7: “Serial no.” refers to the sequence no. of the whole function code,
also indicates the register address of communication.
2)“Parameter system” is the decimal system (DEC), if the parameter adopts
the hexadecimal system, when editing the parameters, the data of every bit
should be independent each other, the numeric area of some bits may be the
hexadecimal system (0~F).
3)“ Default” indicates that the value that the function code parameters have
been refurbished when operation of ex-factory parameter is restored; but, the
actual measured parameter or recorded value can't be refurbished.
4)To get better protection for parameters, the inverter provides the password
protection for the function code. After the user's password has been set (namely,
the parameter of user's password P1.22 is non zero), user presses the
key, the inverter enters into the function code edition state, the system will get
into the user's password verification state first, it displays “ 0.0.0.0.0” , the
operator must correctly input the user's password, otherwise, the system fails to
enter into operation. For the manufacturer's setting parameter area, the operator
also should input the manufacturer's password correctly, thus, the system can
perform the normal operation. (Notice: User should not attempt to amend the
manufacturer's setting parameters, if the parameters haven't been set correctly,
the inverter will work abnormally or it will be damaged easily).
In the unlocking state of password protection, the user's password may be
amended at any time, it is subject to the last input. The user's password may be
canceled by setting P1.22 to 0; when re-electrified, the password goes into effect;
if the P1.22 has not been set to 0, the parameter is protected by the password.
5)When amending the function code parameters by serial communication, the
function of user's password also follows the abovementioned rules.
"PROG"
Chapter 5 Function parameters table
P0 group Basic function group
Function parameters table: 1
Function
group
Function
code
Name
Parameter description
Default
Amen
-dment
Serial no.
Speed control
mode
Frequency
command
selection
Running command
channel
Keyboard setting
frequency
Acceleration time 1
Deceleration time 1
Carrier frequency
setting
V/F curve setting
Torque increase
Cut-off point of
torque increase
Limit point of VF
slip compensation
Running direction
selection
Dead time of forward
/reverse rotation
Max output
frequency
Upper-limit
frequency
Lower-limit
frequency
0: Vector control without PG
1: V/F control
0:Keyboard setting
1:Analog terminal 4 setting
2:Analog terminal 5 setting
3:Terminal 4+ terminal 5
4:Setting of multi-speed running
5:PID control setting
6:Remote communication setting
0:Keyboard command channel
(LOC/REM lamp goes out)
1:Terminal command channel
(LOC/REM lamp flashes)
2:Communication command
channel (LOC/REM lamp goes on)
0.00Hz~P0.13(max frequency)
0:Straight-line type VF curve
1: 2nd power
0.0%:( automatic) 0.1%~30.0%
(related to rated frequency of motor)
0:Default direction running
1:Opposite direction running
2:Forbidden reverse running
0.00Hz~P0.14
(upper-limit frequency)
Depend on the
machine type
Depend on the
machine type
Depend on the
machine type
Depend on the
machine type
Note:
"○"represents the parameter setting values may be amendable when the inverter
is in the shutdown and running state;
"◎"represents the parameter setting values are unallowable to be amended when
the inverter is in the running state;
"●"represents the parameter is unallowable to be amended when it is the actual
measured and recorded value.