Troubleshooting 73
Err no.: Type: Usertext:
6016 E Min. test pressure must be less than max. test pressure
6017 E Limits for BP pressure increment: 25 mbar <= BP pressure increment <= 100 mbar (0.36 psi < BP pressure increment <=
1.45 psi) mbar and hPa values have no decimal places, psi values have up to 2 decimal places.
6018 E Limits for BP FACTOR: 0.1 <= BP FACTOR <= 9.9
6019 E Limits for brief times: 1 sec <= brief stabiliz. time, brief test time <= 999 sec
6020 E Old password wrong! Please try to enter it again or notify your system administrator
6021 E New passwords are not identical! Please try to enter them again or notify your system administrator
6022 E New user ID already exists! Please try again
6023 E New user name already exists! Please try again
6024 E New password is same as old password! Please try again or inform your system administrator
6025 E Your password has expired! Please enter a new password or inform your system administrator
6026 E Wrong password! Please try again or inform your system administrator
6027 E Unknown user! Please add a new user or inform your system administrator
6028 E Log off not possible at the moment! Please try again later.
6029 E Calibration of the internal pressure sensor is due. Please calibrate the sensor.
6030 E Calibration of the internal pressure sensor is due in <ARG1> day. Please calibrate the sensor.
6031 E Calibration of the external pressure sensor input is due. Please calibrate the sensor.
6032 E Calibration of the external pressure sensor inlet is due in <ARG1> day. Please calibrate the sensor.
6033 E The audit trail file is full! Please archive it!
6034 E Limits for BP volume: 10 ml <= vol <= 50000 ml
6035 E Error while setting the date/time for the data management unit
6036 E Wrong parameter for setting the date
6037 E Wrong parameter for setting the time
6038 E Pressure differential after point ‘<ARG1>’ is ‘<ARG2>’ It must be at least as large as ‘<ARG3>’
6039 E Diffusion differential after point ‘<ARG1>’ is ‘<ARG2>’ It must be at least as large as ‘<ARG3>’
6040 E <ARG1> - <ARG2> error when creating program no.!
6041 E Timeout while setting the linearization standard parameters
6042 E Data not automatically stored ‘<ARG1>’ : <ARG2>
6043 E Serious internal error <ARG1> ; <ARG2> ; <ARG3>
6044 E The test program ‘<ARG1>’ could not be saved. <ARG2>
6045 E Error accessing temporary directory
6046 E The test result ‘<ARG1>’ could not be saved. The SD card is full.
6047 E Test unit address must be between range of 1 to 5.
6048 E You do not have sufficient access rights to perform this operation!
6049 E No user is logged in. Please log in first!
6050 E No test has been run yet!
6051 E Filter/system was vented.
6052 R Test passed.
6053 R Operation successful.
6054 R Operation not successful.
6055 R Test failed.
6056 E No test result.
6057 E Print failed, error <ARG1>.
6058 E No test programs were found.
6059 E The requested backup could not be loaded!
6060 E The directory could not be transferred - Please check network connection.
6061 E The temporary backup file could not be created.
6062 E The backup file could not be transferred.
6063 E The value entered is outside the valid range or number of decimals is wrong: <ARG1>