74 Troubleshooting
Err no.: Type: Usertext:
6064 E The cleaning procedure was terminated early. - Close shutoff valve (f) - Disconnect “Venting 1” tubing from pressure tank
(g) Please run drying procedure now.
6065 E The drying process was stopped. Before the next test series, this process must be completely repeated. - Close shutoff valve
(f) - Disconnect “Venting 1” tubing from pressure tank (g) - Disconnect remaining tubing from pressure tank (g). Caution:
Tank (g) is being vented - Please disconnect all tubing from the connectors b-e.
6066 E File number must be between 0 and 5!
6067 E File ‘<ARG1>’ cannot be transferred! ‘<ARG2>’
6068 E There is no SD card inserted in the drive.
6069 E File “<ARG1>” could not be copied!
6070 E File “<ARG1>” does not exist!
6071 E SD card test: User break
6072 E SD card test: error!
6073 E SD card test: error or no SD card in the drive.
6074 E Formatting SD card: SD card is write-protected.
6075 E Error occurred when formatting SD card
6076 E Cannot establish network connection.
6077 E Test result could not be transferred.
6078 E Test result cannot be opened.
6079 R The network connection functional.
6080 E Cannot establish connection to server: <ARG1>
6081 E Writing test unit timer equalization failed ‘<ARG1>’
6084 R Test unit address allocation successful.
6085 E Test unit address allocation not successful.
6086 E The value entered is outside the valid range or number of decimals is wrong: <ARG1>
6087 E Unexpected change in serial number. Expected: ‘<ARG1>’ Now: ‘<ARG2>’
6088 ...
6089
E Unexpected change in test unit status.
6090 E Time exceeded when starting the program.
6091 ...
6092
W File’<ARG1>’ could not be transferred! ‘<ARG2>’ Do you want to cancel the procedure?
6093 W File’<ARG1>’ could not be deleted! Do you want to cancel the procedure?
6094 W Do you really want to change the measurement method?
6096 W Do you really want to delete the entry selected?
6098 W The current parameters are replaced by the factory settings. The parameters changed so far will be overwritten. Do you
really want to do that?
6099 W All data on the SD card will be overwritten. Are you sure you want to overwrite this data?
6100 W This SD card is not suitable for saving Sartocheck4 files. Do you want to reformat the SD card?
6101 W Drying is not performed completely! Do you want to start the test anyway?
6102 W This cancels the ongoing procedure! Do you really want to do this?
6105 W The file ‘<ARG1>’ already exists. Do you want to overwrite it?
6106 W There is no SD card in the drive! Please insert a formatted SD card in the drive to save the data. Do you want to repeat this
procedure?
6107 W There is no SD card in the drive. Please insert a formatted SD card to read the data. Do you want to repeat the procedure?
6108 W There is no properly formatted SD card in the drive! Please insert a formatted SD card to save the data. Do you want to
repeat the procedure?
6109 R Test results not found.
6110 E No function is currently assigned to the stop button. Either no tests are running or visualization is not activated.
6111 E The maximum number of ‘%’ users may not be exceeded.
6112 E SD card is write-protected.
6114 E It is not possible to start the selected procedure at the moment, because the former procedure has not yet been completed
- Please try again later