Unit 4: Standard Command Codes
E/Pro Programming Reference
4-61 PN: 9001096E
NOTES
1. This command supports UPC-A only. Selecting barcode type other than “H” will be a command
error.
2. Recommended narrow bar width for UPC-A with HRI characters:
8 dots/mm resolution [02], [03]
12 dots/mm resolution [03], [04]
3. Refer to the following settings.
4. If a parameter is specified out of the range, its behavior will not be supported.
5. The command <BD> with specifying font type to print UPC-A will print the character bars all in
the same length. On the other hand, the command <BM> will print the start bar and end bar in
the same length as that of guard bars.
When printing UPC-A with command <BD>, its HRI can be printed from under the start/end bar,
because the length of them is short. When printing UPC-A with command <BML>, character
spacing of the HRI will be smaller than command <BL>.
UPC-A BARCODE (WITH HRI)
Barcode setting
oitaR IRH rab drauG
dexiF seY seY