Unit 4: Standard Command Codes
E/Pro Programming Reference
4-77 PN: 9001096E
NOTES
Enter parameters for e, f, and g when selecting 1: Concentration (d), omit them when selecting
0: Normal.
Designation of print data will vary do to the setting of parameter c.
Parameter e allows specification/connection of QR Codes that were partitioned by concentration mode.
Parameter f allows specification of a specifically partitioned QR Code.
Parameter g carries out XOR logic operation of all partitioned print data of the QR Code, then specifies
this operational data in hexadecimal character (parity data).
Parameter k is to only be set if selecting data setting mode as 0: Manual. Binary specification is
available for this setting and its data designation command varies.
Parameter m is to only be set if XXXXXXXXXXXXXXXXXXXXXXXX
When designating a parameter other than specified or when the print data quantity does not match,
printing will not be performed.
For data portion, data designation command varies depending on the parameter setting or the data
selected.
Data Setting 1: Auto or for binary 0: Manual = <ESC>DNmmmm,n...n.
Data Setting for parameters other than binary in 0: Manual =
<ESC>DS1,n...n (Numeric)
<ESC>DS2,n...n (Alphanumeric)
<ESC>DS3,n...n (Kanji)
Enter parameters followed by data. When entering more data, specify the data consecutively or printing
will not be properly performed.
The total print data size (n) is to 7000 bytes. The maximum data blocks that can be entered is 200.
Refer to Appendix: Reference Tables 33 and 34 for additional information.
2D30/31 (QR CODE)