Loading...
Unit 5: Optional Command Codes
E/Pro Programming Reference
5-14 PN: 9001096E
FORM OVERLAY, RECALL
FUNCTION
To recall the label image from stored in the Expanded Memory.
FORMAT
<ESC>&R,aa
aa = Storage number (01 to 99)
Place immediately following the <ESC>CC Memory Area Select command.
EXAMPLE
<ESC>A
<ESC>CC1
<ESC>&R,01
<ESC>Q1<ESC>Z
OUTPUT
This command does not result in printer output.
NOTES
The Expanded Memory option is required fro this command.
The <ESC>CC Memory Area Select command must be sent prior to this command.
Several images stored under different storage numbers can be printed with this command. The storage
number must be speciifed.
A read/write error will occur if an unused storage number is specified.
The label image can be moved by using the <ESC>V and <ESC>H commands when it is stored along
with a window size. If it exceeds the printable area by being moved, the label image will be trancated.