EasyManua.ls Logo

SATO CL612e - User Test Print Function; Download Mode Operations; User Download Mode; Hex Dump Mode Usage

SATO CL612e
290 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Unit 4: Standard Command Codes
E/Pro Programming Reference
4-2 PN: 9001096E
CONTROL COMMANDS
START/STOP LABEL
FUNCTION
For all print jobs, the Start command must precede the data and the Stop command must
follow. The print job will not run properly if these are not in place.
FORMAT
Start Command: <ESC>A
Stop Command: <ESC>Z
<ESC>A must precede data <ESC>Z must follow data.
EXAMPLE
<ESC>A
<ESC>H0001<ESC>V0100<ESC>WB1SATO
<ESC>H0130<ESC>V0200<ESC>B103150*SATO*
<ESC>H0170<ESC>V0360<ESC>L0202<ESC>S*SATO*
<ESC>Q1
<ESC>Z
OUTPUT
This command does not result in printer output.
NOTES
There is no output for these commands they are not accompanied by other label printing commands.
However, these commands must precede and follow each print job sent to the printer.

Table of Contents

Other manuals for SATO CL612e

Related product manuals