Section 7: Interface Specifications
Page 7-4 GY412 Operator Manual
7.3 RS-232C SERIAL INTERFACE (cont’d)
Communication settings
The following items can be set through the interface mode of the printer.
* Ready/Busy and XON/XOFF are not supported in [Protocol].
Item Setting Range
Protocol STATUS3
STATUS4 (Protocol for the driver) (* Default value)
STATUS5
Baud rate 2400bps, 4800bps
9600bps, 19200bps(* Default value)
38400bps, 57600bps
Data bit strength 7 bits, 8 bits (* Default value)
Parity bit NONE (* Default value), ODD, EVEN
Stop bit 1 bit (* Default value), 2 bits
Synchro system Asynchronous method
Maximum receive
buffer capacity
2.95 MB
Code ASCII (7 bits), Graphic (8 bits)
Signal level High level
Low level
: +5V to ~+12V
: -5V to ~+12V
Reception method Multi buffer *Single item buffer is not supported.
Near full occurred
Near full released
0 MB
2.95 M
B
Remaining 0.95 MB
Remaining 1.95 MB